EJOT® Universal anchor SDF-KB-10H
Specification
-
Applications
- Installation of metal attachments
- For multiple fastening of non-load-bearing systems according to EAD 330284-00-0604
- Suitable for the structural fastening of wall cupboards, cladding, metal angle pieces
- For embedment in rain screens
- For application as single fastening in concrete
-
Properties
- Hexagon head with flange
- Approved for all common building materials
- Reliable hold in problematic building material thanks to optimised expansion part
- Radial expansion for reliable hold
- Product identification through different sleeve colours
- Double safety lock against torsion for secure installation
Base materials
Approved for- Cracked concrete
- Non-cracked concrete
- Solid masonry
- Hollow and perforated bricks
- Aerated concrete
Note
For planning and processing, please observe ETA-10/0305 and Z-21.2-2122. Further information about parameters and loads can be found in the approvals. For bricks of unknown quality, the load-bearing capacity must be determined through pull-out tests on the structure. -
Technical specifications
Characteristic values
- Diameter: 10 mm
- Hole depth in concrete h1.1: ≥ 80 mm
- Effective embedment depth hnom: ≥ 70 mm
- Drill hole diameter d0: 10 mm
- Through hole diameter of component to be attached df: ≤ 10.5 mm
- Drive: AF13/T40
Admissible loads
- Tensile load NRk,p in concrete C12/15
- Temperature range 30 °C / 50 °C: 1.79 kN
- Temperature range 50 °C / 80 °C: 1.59 kN
- Brick Mz 20-1.8, NF: 1.14 kN
- Solid sand-lime brick KS 36, NF: 1.29 kN
- Solid sand-lime brick KS 20, 8 DF: 1.29 kN
- Solid lightweight concrete brick V6, 2 DF: 0.57 kN
- Vertically perforated brick HLz 12-0.9, NF: 0.57 kN
- Perforated sand-lime brick KSL 12, 4 DF: 0.71 kN
- Cavity block made of lightweight concrete Hbl 10, 12 DF: 0.34 kN
- Transverse load VRk,s
- Steel screw (γMs = 1.25): 7.48 kN
- Stainless steel screw (γMs = 1.56) 6.99 kN
- Bending moment MRk,s
- Steel screw (γMs = 1.25): 14.14 kN
- Stainless steel screw (γMs = 1.56): 13.22 kN
- Compressive strength aerated concrete [N/mm2]: 30 - 50 °C
Aerated concrete fb ≥ 4 N/mm2: 0.54 kN
Aerated concrete fb ≥ 5 N/mm2: 0.71 kN
Aerated concrete fb ≥ 6 N/mm2: 0.89 kN
Aerated concrete fb ≥ 7 N/mm2: 0.89 kN
Further lengths available upon request
Filter
Selected filters
Orderidentifier | Article Number | ø mm | Material | Length mm | Clamping thickness tfix≤ mm |
Unit |
---|---|---|---|---|---|---|
SDF-KB-10Hx80-V | 8513080420 | 10.0 | Carbon Steel | 80.0 | 10.0 | 100 |
Specifications
|
||||||
SDF-KB-10Hx80-E | 8513080620 | 10.0 | Stainless Steel | 80.0 | 10.0 | 100 |
Specifications
|
||||||
SDF-KB-10Hx100-V | 8513100420 | 10.0 | Carbon Steel | 100.0 | 30.0 | 50 |
Specifications
|
||||||
SDF-KB-10Hx100-E | 8513100620 | 10.0 | Stainless Steel | 100.0 | 30.0 | 50 |
Specifications
|
||||||
SDF-KB-10Hx120-V | 8513120420 | 10.0 | Carbon Steel | 120.0 | 50.0 | 50 |
Specifications
|
||||||
SDF-KB-10Hx120-E | 8513120620 | 10.0 | Stainless Steel | 120.0 | 50.0 | 50 |
Specifications
|
||||||
SDF-KB-10Hx140-V | 8513140420 | 10.0 | Carbon Steel | 140.0 | 70.0 | 50 |
Specifications
|
||||||
SDF-KB-10Hx140-E | 8513140620 | 10.0 | Stainless Steel | 140.0 | 70.0 | 50 |
Specifications
|
CAD
* Thank you for your interest in our CAD data. To be able to use this area, simply log in or please register here.
CAD & more - Your Online Service Area
Unfortunately you currently have no authorization to use "CAD & more".
Unfortunately, this data can not be provided to you without the consent of the confidentiality agreement.
Your request will be manually verified, this can take 1 to 3 business days.
-
For technical questions please contact our Hotline Team +49 2751 529-123
Problems with your access? Mail to: service-industrie@ejot.com
Grant Access to CAD Data
Unfortunately you currently have no authorization to use "CAD & more".
Apply for access to CAD data.
-
For technical questions please contact our Hotline Team +49 2751 529-123
Problems with your access? Mail to: service-industrie@ejot.com
Thank you!
Your request will be manually verified, this may take 1 to 3 business days.
You will receive an e-mail as soon as your access for "CAD & more" has been activated.
Thank you for your patience.
-
For technical questions please contact our Hotline Team +49 2751 529-123
Problems with your access? Mail to: service-industrie@ejot.com
Confirm CAD data renewal
In the e-mail sent by us you will find the link to verify your account, please click on it.
If you do not receive an e-mail within a few minutes, please check your spam folder.
-
For technical questions please contact our Hotline Team +49 2751 529-123
Problems with your access? Mail to: service-industrie@ejot.com
Can not be renewed
Please contact our customer care
-
For technical questions please contact our Hotline Team +49 2751 529-123
Problems with your access? Mail to: service-industrie@ejot.com
Can not process your request for CAD
Please contact our customer care
-
For technical questions please contact our Hotline Team +49 2751 529-123
Problems with your access? Mail to: service-industrie@ejot.com