EJOT® universal anchor SDF-KB-10H/M8
Specification
-
Applications
- Suitable for installation of support profiles with steel rods in rainscreen
- Embedment of suspended ceilings
- Fastening of ring bolts
Notice
Please observe the European Technical Approval ETA-10/0305 in the planning and processing of products. Further information about parameters and loads can be found in the approval under the tab "Download".
* The load-carrying capacity and the influence of larger embedment depths in hollow or perforated brick (hnom > 70 mm) and/or different stones (acc. to ETA-10/0305 with regards to stone size, compression strength and hole pattern) has to be determined with tests on the building.
-
Properties
- With M8 threaded connection
- Approved for all common building materials
- Reliable hold in problematic building material thanks to optimised expansion part
- Radial expansion for reliable hold
- Product identification through different sleeve colours
- Double safety lock against torsion for secure installation
-
Technical specifications
Characteristic values
- Diameter: 10 mm
- Drill hole depth: ≥ 90 mm
- Effective embedment depth hnom: ≥ 70 mm
- Drill-hole diameter d0: 10 mm
- Through hole diameter of component to be attached df: ≤ 10.5 mm
- Drive: AF 13
- Length M8 threaded connection: 13 mm
Characteristic loads
- Tensile load NRk,p in concrete C12/15
- Temperature range 30 °C / 50 °C: 4.50 kN
- Temperature range 50 °C / 80 °C: 4.00 kN
- Brick Mz 20-1.8, NF: 4.00 kN
- Solid sand-lime brick KS 36, NF: 4.50 kN
- Solid sand-lime brick KS 20, 8 DF: 4.50 kN
- Solid lightweight concrete brick V6, 2 DF: 2.00 kN
- Vertically perforated brick HLz 12-0.9, NF: 2.00 kN
- Perforated sand-lime brick KSL 12, 4 DF: 2.50 kN
- Cavity block made of lightweight concrete Hbl 10, 12 DF: 1.20 kN
- Transverse load VRk,s
- Anchor with A4 stainless steel screw: 10.91 kN
- Bending moment MRk,s
- Anchor with A4 stainless steel screw: 20.62 kN
- Compressive strength aerated concrete [N/mm2]: 30 - 50 °C
- Aerated concrete 4: 1.5 kN
- Aerated concrete 5: 2.0 kN
- Aerated concrete 6: 2.5 kN
- Aerated concrete 7: 2.5 kN
- Partial safety factor γMAAC: 2.0
Filter
Selected filters
Orderidentifier | Article Number | Material | Length mm | Unit |
---|---|---|---|---|
SDF-KB-10Hx80/M8x13-E | 8513080813 | Stainless Steel | 80.0 | 100 |
Specifications
|
||||
SDF-KB-10Hx100/M8x13-E | 8513100813 | Stainless Steel | 100.0 | 50 |
Specifications
|
CAD
* Thank you for your interest in our CAD data. To be able to use this area, simply log in or please register here.
CAD & more - Your Online Service Area
Unfortunately you currently have no authorization to use "CAD & more".
Unfortunately, this data can not be provided to you without the consent of the confidentiality agreement.
Your request will be manually verified, this can take 1 to 3 business days.
-
For technical questions please contact our Hotline Team +49 2751 529-123
Problems with your access? Mail to: service-industrie@ejot.com
Grant Access to CAD Data
Unfortunately you currently have no authorization to use "CAD & more".
Apply for access to CAD data.
-
For technical questions please contact our Hotline Team +49 2751 529-123
Problems with your access? Mail to: service-industrie@ejot.com
Thank you!
Your request will be manually verified, this may take 1 to 3 business days.
You will receive an e-mail as soon as your access for "CAD & more" has been activated.
Thank you for your patience.
-
For technical questions please contact our Hotline Team +49 2751 529-123
Problems with your access? Mail to: service-industrie@ejot.com
Confirm CAD data renewal
In the e-mail sent by us you will find the link to verify your account, please click on it.
If you do not receive an e-mail within a few minutes, please check your spam folder.
-
For technical questions please contact our Hotline Team +49 2751 529-123
Problems with your access? Mail to: service-industrie@ejot.com
Can not be renewed
Please contact our customer care
-
For technical questions please contact our Hotline Team +49 2751 529-123
Problems with your access? Mail to: service-industrie@ejot.com
Can not process your request for CAD
Please contact our customer care
-
For technical questions please contact our Hotline Team +49 2751 529-123
Problems with your access? Mail to: service-industrie@ejot.com